Interfaces; Parallel Interface - Epson STYLUS 3000 Service Manual

Epson printer user manual
Table of Contents

Advertisement

Product Descriptions

1.4 Interfaces

The EPSON Stylus COLOR 3000 is equipped with the parallel and Mac serial interfaces and a card slot
for an optional Type-B interface. This section provides information on each interface.

1.4.1 Parallel Interface

Forward Channel

Transmission mode

Synchronization

Handshaking

Signal level

Adaptable connector
Table 1-19. Signal level of TTL Compatible (IEEE-1284 level 1 device)
Parameter
VOH*
VOL*
IOH*
IOL*
CO
VIH
VIL
IIH
IIL
CI
A LOW logic level on the Logic H signal is as follows:
2.0 V or less when the printer is powered off.
3.0 V or more when the printer is powered on.
The receiver provides an impedance equivalent to 7.5 K ohms to ground.
The BUSY signal is set HIGH before setting either /ERROR LOW or PE HIGH and held HIGH until all
these signals return to an inactive state. The BUSY signal is HIGH in the following cases:

During data entry.

When the input data buffer is full.

While /INIT signal is at low level or during hardware initialization.

During a printer error condition (See /ERROR signal).

During test printing.

When the printer is in default setting mode.

When the parallel interface is not selected.
The /ERROR signal is LOW when one of the following errors has occurred:

Printer hardware error (fatal error)

Paper-out error

Paper-jam error

Ink-out error
The PE signal is high level during paper-out error.
1-16
8 bit parallel, IEEE-1284 compatibility mode
By /STROBE pulse
By /BUSY and /ACKNLG signal
TTL compatible
57-30360 (Amphenol) or equivalent
Minimum
-
-0.5 V
-
-
-
-
0.8 V
-
-
-
Maximum
Condition
5.5 V
-
0.32 mA
VOH = 2.4 V
12 mA
VOL = 0.4 V
50 pf
2.0 V
-
0.32 mA
VIH = 2.0 V
12 mA
VIL = 0.8 V
50 pf
Rev. A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stylus color 3000

Table of Contents