Electric Specifications; Environmental Conditions - Epson STYLUS 3000 Service Manual

Epson printer user manual
Table of Contents

Advertisement

Product Descriptions

1.3.10 Electric Specifications

120 V version

Rated voltage

Input voltage range

Rated frequency renege

Input frequency range

Rated current

Power consumption

Insulation resistance

Dielectric strength
220 - 240V version

Rated voltage

Input voltage range

Rated frequency renege

Input frequency range

Rated current

Power consumption

Insulation resistance

Dielectric strength

1.3.11 Environmental Conditions


Temperature

1
Operating*

2
Non operating*

Humidity

1
Operating*

2
Non operating*

Resistance to vibration

Operating

2
Non-operating*

Resistance to shock

Operating

2
Non-operating*
*1 :Refer to the table below for guaranteed range.
*2 :In shipment container.
1-14
AC 120 V
AC 103.5 to 132 V
50 to 60 Hz
49.5 to 60.5 Hz
0.7 A (maximum)
Approximately 21 W (ISO/IEC 10561 Letter pattern)
Energy Star program compliant
10 M ohms min. (Between AC line and chassis, 500 VDC)
AC 1,000 V rms. For 1 minute or
AC 1,200 V rms. For 1 second (Between AC line and chassis)
AC 220 to 240 V
AC 198 to 264 V
50 to 60 Hz
49.5 to 60.5 Hz
0.4 A (maximum)
Approximately 21 W (ISO/IEC 10561 Letter pattern)
Energy Star program compliant
10 M ohms min. (Between AC line and chassis, DC 500 V)
AC 1,500 Vrms. For 1 minute (Between AC line and chassis)
10 C to 35 C
-20 C to 60 C
1 month at 40 C (104 F)
120 hours at 60 C (140 F)
20% to 80% RH (without condensation)
5% to 85% RH (without condensation)
0.15 G
0.50 G
1 G within 1 ms
2 G within 2 ms
Figure 1-7. Environmental Conditions
Rev. A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stylus color 3000

Table of Contents