Clean-up configuration tasks
After initially configuring the host and MSA, to complete the configuration, be sure to:
•
Check the SMU to ensure that all initiators have been added.
•
Verify in the initiator software that the 1510i targets are present.
•
Logon to the available targets.
•
Ensure that the connection is automatically restored when the system boots.
•
Set up security measures (ACLs, VLANS, and CHAP).
•
In active/active multipath environments, distribute ownership of the LUNs between the two MSA
controllers. Choose one of the following:
• Automatic (also called implicit) load balancing (default)—MSA firmware automatically
reassigns LUN ownership evenly between the controllers based on I/O loads of the LUNs.
(Recommended)
• Manual (also called explicit) load balancing—Through the SMU or the CLI, indicate the
preferred path (controller ownership) for each LUN.
Configuring the Microsoft iSCSI initiator
IMPORTANT:
When installing the multipathing components, be sure to install Both the DSM and the MPIO core
components.
If you are unfamiliar with the configuration and use of Microsoft's iSCSI initiator software, this section
describes how to configure the Microsoft iSCSI initiator to connect to a dual-controller MSA1510i in a
multipathing environment. (For single-controller configurations, omit all steps shown for multipath or
dual-controller configurations.)
For more information, see the iSCSI initiator user documents or online help.