HP StorageWorks 1510i - Modular Smart Array User Manual page 24

Active/active firmware v2.0 or later
Hide thumbs Also See for StorageWorks 1510i - Modular Smart Array:
Table of Contents

Advertisement

Item 1
Item 2
Activity LED
Online LED
nl
nl
On
Off
Blinking
Blinking
Off
Off
On or off
Blinking
Off
Off
Off, on, or
On
blinking
Off, on, or
On or off
blinking
24
System components and LEDs
Item 3 Fault
Meaning
LED
nl
The hard drive is being accessed in one of the following ways:
The hard drive is not configured as part of an array.
The hard drive is a replacement and rebuild has not yet started.
Off
The hard drive is spinning up during POST.
Do not remove the hard drive. Removing a hard drive at this time could
terminate the current operation and cause data loss.
The hard drive is being accessed in one of the following ways:
The hard drive has been selected for identification in HP-SIM,
MSA-CLI, or other supported management utility.
Blinking
The hard drive is being upgraded.
Do not remove the hard drive. Removing a hard drive at this time can
cause data loss in non-fault-tolerant configurations.
The hard drive is not being accessed and is not configured as part of an
array. If necessary, it is safe to replace the hard drive. This hard drive
is in one of the following states:
Off
The hard drive is not configured as part of an array.
The hard drive is configured as an online spare.
The hard drive is being accessed in one of the following ways:
The hard drive is a replacement hard drive and is being rebuilt.
If the online LEDs of all of the other hard drives in the array are
Off
blinking, an expansion is occurring.
Do not remove the hard drive. Removing a hard drive at this time can
cause data loss.
The hard drive has failed and has been placed offline. It is safe to
On
replace the hard drive.
The hard drive is online and configured as part of an array, If necessary,
and if all other hard drives in the same array are online and working, it
is safe to replace the hard drive. one of the following is happening:
Off
If the Activity LED is off, the drive is configured and online but not
currently active.
If the Activity LED is on or blinking, the drive is configured, online,
and currently active.
A predictive failure alert has been received for this drive. Replace the
Blinking
hard drive as soon as possible.

Advertisement

Table of Contents
loading