HP StorageWorks 1510i - Modular Smart Array User Manual page 127

Active/active firmware v2.0 or later
Hide thumbs Also See for StorageWorks 1510i - Modular Smart Array:
Table of Contents

Advertisement

Message
522 INITIALIZING
ISCSI SUBSYSTEM
523 LOADING ISCSI
PARAMS
524 ISCSI MODULE
HARDWARE FAILURE
525 ISCSI MODULE
BIST FAILED
526 ETHERNET
MODULE DETECTED
527 ETHERNET
MODULE MISSING
528 ETHERNET
MODULE INVALID
600 INITIALIZING
TARGET-BASED MGMT
601 PORT <n> LINK
FAILURE
602 PORT <n> LINK
OK <speed> Mb/s
603 PORT <n> IP
<ip>
604 PORT <n> DHCP
FAILED
605 MANAGEMENT
PORT <n> ENABLED
606 MANAGEMENT
PORT <n> DISABLED
607 NO MANAGEMENT
HARDWARE FOUND
Type
Description
The iSCSI subsystem is being
Informational
initialized as part of the power-on
sequence.
The iSCSI configuration is being
Informational
loaded into the iSCSI hardware as
part of the power-on sequence.
The array controller has detected
Error
a hardware failure in the iSCSI
daughter board.
The iSCSI daughter board has
Error
detected a failure during its Built
In Self Test (BIST).
A 2-Port Ethernet iSCSI module has
Informational
been inserted or detected during
POST.
No 2-Port Ethernet iSCSI
module was detected during
Error
POST. Network connectivity is
unavailable.
The module in the Ethernet module
bay is not a valid 2-Port Ethernet
Error
iSCSI module, or the module has
failed.
The Target-Based Management
Informational
subsystem is being initialized as
part of the power on sequence.
The MSA has detected a link
Error
failure on the indicated GBE port.
The MSA has detected an active
Informational
link on the indicated GBE port.
The management IP address on the
indicated port has been changed,
Informational
and the new address is displayed
for user reference.
The MSA has failed to obtain an IP
address for the management port
Error
via DHCP, and will fall back to
zeroconf IP address.
The MSA has enabled
management access through
the indicated port as part of the
Informational
power on sequence or due to a
hardware failure on the configured
port.
The MSA has disabled
management access through
Informational
the indicated port.
The array controller is unable
to locate any Ethernet hardware
that can be used to provide
Error
management access. Target-Based
Management functionality is
disabled.
1510i Modular Smart Array installation and user guide
Action
Contact HP support.
Contact HP support.
Insert a 2-Port Ethernet iSCSI
module into the appropriate slot in
the rear of the chassis.
Verify that the module is inserted
properly into the bay. If the
problem persists, replace the
module.
Check the network cable attached
to the port.
Check that a DHCP server exists
on your network, or reconfigure
Target-Based Management to use
a static IP address.
Contact HP support.
127

Advertisement

Table of Contents
loading

Table of Contents