Chassis specifications
Parameter
Height
Width
Depth
Weight
Input voltage requirements
Rated input voltage
Rated input frequency
Rated input current
Input power (max)
Power supply specifications
Rated steady-state power
Maximum peak power
BTUs
Temperature range
Operating
Shipping
Relative humidity (noncondensing)
Operating
Non-operating
Maximum wet-bulb temperature
Long term storage
Short term storage
Idle
Fixed drive (random writes)
* Input power and heat dissipation specifications are maximum values and apply to worst-case conditions
at full rated power supply load. The power/heat dissipation for your installation varies depending on the
equipment configuration.

Preparing the network

Preparing the network for the MSA1510i includes:
• Preparing the servers
• Preparing the switches
NOTE:
For optimum network performance, use 1000BaseT Ethernet NICs, 1000BaseT switches, and qualified
Category 5e (or better) cables throughout the network.
38
Installation
Value
8.78 cm (3.46 in.)
48.41 cm (19.06 in.)
61.77 cm (24.32 in.)
24.95 kg (55 lb)
100 to 240 VAC
47 Hz to 63 Hz
6.4A Max, 1A typical
400W Max, 95W typical
377 watts
681 watts
2187 BTU/hr*
10° to 35°C (derated 1°C per 1000 feet of elevation
to 10000 ft.); (50° to 95°F)
-30° to 50°C (-22° to 122°F)
10% to 90%
Up to 95%
29°C (84.2°F)
30°C (86°F)
<6.9 and 53
<7.3 and 54