HP StorageWorks 1510i - Modular Smart Array User Manual page 120

Active/active firmware v2.0 or later
Hide thumbs Also See for StorageWorks 1510i - Modular Smart Array:
Table of Contents

Advertisement

Message
121 NO VOLUMES
DETECTED
122 NEW VOLUME(S)
DETECTED
123 TOO MANY
VOLUMES DETECTED
124 SPARES CLEARED
125 ACCESS CONTROL
CONFLICT DETECTED
126 ACCESS CONTROL
RESOURCES EXCEEDED
120
MSA controller LCD panel message descriptions
Type
Description
No configured volumes were
Informational
detected at power-up.
Configured volumes from another
array controller were migrated
Informational
to this array controller. The
configuration information has been
updated.
The array controller supports
a maximum of 32 configured
volumes. More than 32 volumes
were detected at power up. This
typically occurs when migrating
Error
a set of volumes from one
array controller to a different
array controller that already has
configured volumes on it. The
migrated volumes have not been
added.
A set of volumes has been
migrated from one array controller
to a different array controller that
already has configured volumes
on it. The migrated volumes have
Informational
spares defined for them that conflict
with the existing configuration. The
defined spares have been deleted
so as to allow the migration to
proceed.
A set of volumes have been
migrated from one array controller
to a different array controller that
already has configured volumes
on it. The migrated volumes have
Error
access controls defined for them
that conflicts with the existing
configuration. The access controls
have been modified so as to allow
the migration to proceed.
A set of volumes have been
migrated from one array controller
to a different array controllers that
already has configured volumes
on it. The migrated volumes have
Error
access controls defined for them
that conflicts with the existing
configuration. The access controls
have been modified so as to allow
the migration to proceed.
Action
If there are supposed to be
configured volumes, power off the
MSA and then all attached storage
enclosures. Unplug and reinsert all
SCSI hard drives ensuring they are
fully seated in their bays. Check
the cables connecting the MSA to
any attached storage enclosures.
Power on the attached enclosures
and then the MSA.
Remove the migrated volumes and
run the HP Storage Management
Utility or MSA-CLI. Delete any
unneeded volumes until the
number of existing volumes plus
the number of migrated volumes is
32 or less.
Run the Storage Management
Utility (SMU) or MSA Command
Line Interface (MSA-CLI) to reassign
spare hard drives as needed.
Run the HP Storage Management
Utility or MSA-CLI to check the new
access controls and modify them
if needed.
Run the HP Storage Management
Utility or MSA-CLI to check the new
access controls and modify them
if needed.

Advertisement

Table of Contents
loading

Table of Contents