HP StorageWorks MPX200 Solution Manual page 213

Hp storageworks mpx200 multifunction router data migration solution guide (5697-0701, october 2010)
Hide thumbs Also See for StorageWorks MPX200:
Table of Contents

Advertisement

13.
Refresh the data migration user interface to see if the LUN assignment is reflected properly and
that the appropriate array entity appears under FC Array. You may have to reboot the MPX200
or generate a registered state change notification (RSCN) to initiate a full rescan on the HP
StorageWorks XP array, This is necessary because the XP array does not send any notification
indicating changes in LUN assignment to the logged in initiators.
MPX200 Multifunction Router Data Migration
213