The commands in Figure 8.1 in order of appearance. (Audit Report fields shown in
bold)
&&??&%
&%STFPASSWORD$
&%SMCP0001$
&%SAR$
&%STP10001$
&%STP00200$
&%1B26...3358$
&%SQ1200$200
&%1B$(s1p16v0s3b4148T
&%1B$(3@
&%SQ6October 5, 2005$
&%SMF$2014.44~
&%1B$(s0p12h10v1s0b4099T PCL command to change the font to Courier 12 pitch Italic.
&%1B$(3@
&%SQ4$2104.44~
&%SQ3Vendor Systems $
Secure MICR Printer User's Guide
September 2005
Hex transfer enable.
Password command.
MICR definition command with the count set to one.
Activates Audit Report recording.
Unlock flash resource number 10001.
Unlock flash resource number 200.
PCL sequence in hex which sets the page format and enables
macro number 10001.
Stores the vendor number 200 in the first position of the Audit
Report. Note that this field will not be sent to the page to be
printed. Here we send the field again so that it will print.
PCL sequence which changes the font to Univers 16 point.
After the check serial numbers prints (100), the printer is
returned to its default font with the following command.
PCL command to return to default font.
Stores the date in the sixth position of the Audit Report.
Prints Secure Font command. NOTE: Tilde (~) is command
terminator.
See print PCL Fonts on the Front Panel under the test menu
for a printout with their call commands.
PCL command to return to the default font.
Stores the amount in the fourth position of the Audit Report.
Stores the payee, Vendor Systems, in the third position of the
Audit Trail report.
43
© Source Technologies
All Rights Reserved