Audit Report Field Five
&%SQ5
d..d
$
This command identifies the data to be printed in the fifth column of the report. This field is a
maximum of eight characters.
Audit Report Field Six
&%SQ6
d..d
$
This command identifies the data to be printed in the sixth column of the report. This field is
a maximum of 19 characters.
Audit Report Field Seven
&SQ&7
d..d
$
This command identifies the data to be printed in the seventh column of the report. This field
is a maximum of 12 characters. The data in this field is recorded for the Audit Report only.
Print and Purge Audit Report
&%SPURGE
x
$
This command prints and purges the Audit Report. All recorded information is deleted. The
optional field can be any combination of the following letters:
T
Total Field 4
O
Overlay
S
Sort by MICR line
C
Communicate - send report to host instead of printing - see additional
information below on SPRINT command
Secure MICR Printer User's Guide
September 2005
&%SQ5d..d$
Lead in sequence
Data to be printed
Command terminator
&%SQ6d..d$
Lead in string
Data to be printed
Command terminator
&%SQ7d..d$
Lead in string
Data to be stored
Command terminator
&%SPURGExx$
Lead in string
option(s)
Command terminator
39
© Source Technologies
All Rights Reserved
Need help?
Do you have a question about the ST9530 and is the answer not in the manual?
Questions and answers