Chapter 1 About ETERNUSmgr
>

1.2 ETERNUSmgr Functions

Managing Server communication
Communication
Target Device
(ETERNUS2000)
Target Device
(Other than
ETERNUS2000)
Mail Server
(Windows version
only)
*1:
Port number can be changed for the ETERNUS DX400 series, ETERNUS DX8000 series,
ETERNUS4000 models 300, 400, 500, and 600, and ETERNUS8000.
*2:
Default value (port number can be changed depending on the mail server program)
Set firewall as necessary when E-mails are to be relayed between servers.
1.2
ETERNUSmgr Functions
ETERNUSmgr provides the following three functions.
Target Device Configuration Browser
Target Device Monitoring and Failure Notification
Target Device Setup and Maintenance
Target Device Configuration Browser
This displays the hardware structure of the target devices.
Target Device Monitoring and Failure Notification
Target device failure is monitored for. When a failure occurs, a history of the fault is saved as an
HTML file (called an "alarm history file" from here on), and the administrator is notified by E-mail
of the file's location and content. As the alarm history file is kept for a fixed period of time, the
administrator can browse the failure history later, as time permits.
The error monitoring function records the enclosure number where the error occurred. The error
monitoring function can detect only the error location in terms of drive enclosures, controller
enclosures, and battery enclosures, not detailed error location such as hard disk, CPU, etc. To
obtain detailed location once an error is detected, please use ETERNUSmgr's [Device Status
Display] window (the window in which the entire device is displayed).
Specifically, when an error has been detected, the red warning lamp for an enclosure (Drive
Enclosure, Controller Enclosure, Battery Enclosure) on the [Device Status Display] window is
activated. For details on the [Device Status Display] window, see "ETERNUSmgr User Guide -
Settings/Maintenance-".
The extent to which a device can be monitored depends on its model number. Components that
can be monitored for each type of target device are shown in the following list.
P2X0-0202-04ENZ0
ETERNUS Disk storage systems ETERNUSmgr User Guide -Introduction-
Port No./
target
Protocol
80/tcp
80/tcp (*1)
25/tcp (*2)
Communication
direction
Managing Server →
Target Device
Managing Server →
Target Device
Managing Server →
Mail Server
10
Function
Device monitoring
Device monitoring
Mail notification