Table 1.2 Di Port Specifications; Table 1.3 Lan Port Specifications; Table 1.4 Pwc Port Specifications - Fujitsu ETERNUS DX60 S2 User Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX60 S2:
Table of Contents

Advertisement

Chapter 1 Hardware Configurations
1.1 Controller Enclosure
Drive interface ports
A DI port is used to connect a drive enclosure.
The following table shows the DI port specifications.
Table 1.2
SAS
LAN ports
Two LAN ports (RJ-45) are installed in each controller.
Regions other than EMEA&I
Each LAN port is used for operation management (MNT port) and for remote support function
(RMT port) respectively.
EMEA&I region
The MNT port is used for operation management and the RMT port is used for maintenance.
The following table shows the LAN port specifications.
Table 1.3
Ethernet
(1000Base-T/100Base-TX/10Base-T)
SCU
A System Capacitor Unit (SCU) is installed in a controller as a backup power source in case of
power outage.
The SCU is charged from an external power source while the ETERNUS DX Disk storage sys-
tem is running normally. If a power failure is detected, data in the cache memory is saved to the
non-volatile memory in the controller using the SCU. There is no limit to the post-failure data
retention time.
PWC ports
A PWC port is installed in a controller.
The PWC port is used to connect a power synchronized unit to perform power synchronization.
The following table shows the PWC port specifications.
Table 1.4
RS232C
ETERNUS DX60 S2 Disk storage system User's Guide -Site Planning-
DI port specifications
Transfer
Interface
speed (max.)
3Gbit/s
LAN port specifications
Interface
PWC port specifications
Interface
Copyright 2012 FUJITSU LIMITED
Connector type
miniSAS (SFF8088)
1
Transfer
Connector type
speed (max.)
1Gbit/s
RJ-45
Number of ports for
Connector type
each controller
D-sub9 pin
1
17
Number of ports for each controller
Number of ports
for each controller
2
P3AM-5492-04ENZ0