DRAINING THE UNIT

During the cooling process, some water will be extracted from the air and stored within
the unit's water reservoir.
If the water reservoir is full, both the compressor and motor will stop and the unit will
beep (press any button to stop the beeping sound). The full water tank indicator light
will also start flashing.
To resume cooling, empty the reservoir by following these steps:
1. Turn off the air conditioner and unplug
it from the wall socket. To prevent
water leakage, avoid moving the unit
when full.
2. Place a container (such as a small pan)
underneath the drainage hole.
3. Remove the drain knob and rubber
plug from the drainage hole and allow
the water to drain out.
4.
When the container is almost full, place
the rubber plug back into the drainage
hole, empty the container, and place
the drain knob back over the rubber
plug.
5.
Repeat these steps until the water
reservoir is completely empty.
6. Replace the rubber plug and make
sure it is firmly in place.
7. Turn the unit back on. The full tank
indicator light should now turn off.