Drain Kit Installation - Friedrich WallMaster PTAC Installation & Operation Manual

Packaged terminal air conditioners & heat pumps
Hide thumbs Also See for WallMaster PTAC:
Table of Contents

Advertisement

External Drain (for new construction or unit replacement)
When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve. Select
the drain hole which best meets your drainage situation and install the drain kit. Seal off the other with a cover plate.
Drain Tube Installation
1.
Peel the backing tape off the gaskets and apply the sticky
side to one cover plate and one mounting plate as shown
in Details A and B.
2.
Place the drain tube through the gasket and the mounting
plate with the flange toward the wall sleeve.
3.
Attach the drain tube assembly to one of the two drain
holes at the rear of the wall sleeve. The large flange on
the mounting plate is positioned at the bottom of the sleeve
facing toward the sleeve, Detail B. When the drain tube is
positioned at the desired angle, tighten the screws.
NOTE: If the wall sleeve has not been installed, the drain tube must
be rotated to a horizontal position until after the sleeve
is installed. Tighten the mounting plate screws when the
tube is in the proper position. Make certain that the four
overflow slots at the rear of the wall sleeve are not blocked.
(See the drawing below.)
Figure 4

Drain Kit Installation

NOTES:
The large flange on the mounting plate is positioned at the bottom of the sleeve facing toward the sleeve. The drain tube must be rotated to a horizontal
position to allow for the wall sleeve to be installed into the wall. Once the wall sleeve is installed, return the drain tube to a downward angle.
6
Foam gasket
Mounting plate
920-087-02 (9-03)
Cover Plate Installation
4.
Mount the foam gasket to the cover plate. Using two #10 x
1/2" sheet metal screws (provided), attach the cover plate
to the remaining drain hole. Make certain the large flange
on the plate is positioned at the bottom of the sleeve.
5.
Discard the additional cover plate, gasket, machine screws,
and locknuts.
QUANTITY
2
1
1
3
4
2
2
DETAIL B
PXDR1O
DESCRIPTION
COVER PLATES
MOUNTING PLATE
DRAIN TUBE
MOUNTING PLATE GASKETS
#10 X 1/2" MOUNTING SCREWS
10-24 X 1/2" MACH. SCREWS
LOCKNUTS
Foam gasket
Mounting plate
DETAIL A
1
/
" O.D. tube
2
#10 sheet metal screws

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents