Wall Sleeve Installation Instructions (PXWS)
NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories.
If the sleeve projects more than 8" into the room, a subbase or other means of support MUST be used. Please read these instructions
completely before attempting installation.
Figure 5
Typical Wall Sleeve Installation
Lintel to support masonry walls
Electrical receptacle
For Deep Wall Installation See Section II
The following instructions apply ONLY to walls less than
13 1/4" in depth.
1.
From inside the building, position the wall sleeve in the opening
and push it through the wall so it protrudes at least 1/4" on the
outside, note Figure 5.
2. Position the wall sleeve with a slight tilt towards the outside to
facilitate condensate drainage. It should be level side-to-side
and the front should be 1/4 bubble higher than the back. DO
NOT allow any pitch toward the inside.
920-087-02 (9-03)
Wall sleeve
Wall opening
161⁄4"
(41.3 cm)
Insulation
Smooth side of screw
clip facing into room
Electrical shock hazard.
Turn electric power OFF at the fuse box or service panel
before making any electrical connections and ensure a
proper ground connection is made before connecting line
voltage. Failure to do so can result in property damage,
personal injury and/or death.
Electrical receptacle
Insulation
7