Installation; Installing The Local Unit; Connect The Cat5 Cable; Figure 1- Install Local Unit To 2 Gang Outlet Box - Network Technologies XTENDEX ST-C5VA-WL500 Installation And Operation Manual

Xtendex series wall mount vga video and stereo audio extender
Table of Contents

Advertisement

NTI XTENDEX Wall Mount Extenders

INSTALLATION

Installing The Local Unit

Connect The CAT5 Cable

A CAT5 cable with an RJ45 connector wired straight through (see specification on page 10) should extend from a UL
Listed 2 gang electrical box at least far enough to make connection to the RJ45 connector on the back of the Local Unit
(see Fig. 1). The outlet box must be at least 2 inches deep.
1. Connect the CAT5 cable to the Local Unit. When properly inserted the cable end should snap into place.
!
WARNING: Never connect the XTENDEX to an Ethernet card, Ethernet router, hub or switch or other
Ethernet RJ45 connector of an Ethernet device. Damage to devices connected to the Ethernet may result.
2.
Secure the Local Unit to the 2 gang outlet box using the 6-32X1/2" Phillips Flat Head screws (4) provided.
2 Gang Outlet Box (Min. 2" deep)
2 Gang Cover Plate
Cat5 Cable
(from Remote Unit)

Figure 1- Install Local Unit to 2 gang outlet box

4
6-32 X 1/2" Flat Head Screws
(SUPPLIED)
ST-C5VA-500WL
Local Unit