APPLYING POWER (Side View)
Note: Only 1 power supply must be connected to power for minimal operation. For redundant power
operation, V
and V
1
2
current from both sources simultaneously. Use 16-28 gauge wire when connecting to the power supply.
Recommended 24V DC Power Supplies, similar to: N-Tron‟s P/N NTPS-24-5
 Input AC 100V...240V
 Output DC 24V...28V
 Output Current 5A
 Peak Current 7.5A for 4 sec.
(Revised 2011-07-20)
inputs must be connected to separate DC Voltage sources. This device will draw
 Unscrew & Remove the DC Voltage Input Plug
from the Power Input Header
 Install the DC Power Cables into the Plug
(observing polarity).
 Plug the Voltage Input Plug back into the Power
Input Header.
 Tightening torque for the terminal block power
plug is 0.5 Nm/0.368 Pound Foot.
 Verify the Power LED stays ON (GREEN).
 Power 120W
 Peak Power 180W (max 4 sec.)
 35 mm DIN-Rail Mountable
 Dimensions: 1.57"W x 4.88"H x 4.61"D