PLC-XD2200/2600
Expand Serial Command Functional Specifications
8.10.24 CF_FANCONTROL Command
Command
"CF_FANCONTROL_%1"[CR]
"OFF" ---------------------------- Set Fan control to Off
%1
"ON1" ---------------------------- Set Fan control to On1
"ON2" ---------------------------- Set Fan control to On2
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.25 CF_DELAYCTRL Command
Command
"CF_DELAYCTRL_%1"[CR]
"ON" --------------------------- Set Video delay control On
%1
"OFF" -------------------------- Set Video delay control Off
Set Video delay control.
Details
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF. This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.26 CF_CCAPTIONDISP Command
Command
"CF_CCAPTIONDISP_%1"[CR]
"OFF" ------------- Select Off
"CC1" ------------- Select CC1
%1
"CC2" ------------- Select CC2
"CC3" ------------- Select CC3
"CC4" ------------- Select CC4
Select channel of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
Details
This command is available in normal Power ON status.
Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video) and System is fixed
to NTSC i.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
41 / 71