PLC-XU116 Expand Serial Command Functional Specifications
8.10.24 CF_FANCONTROL Command
Command
"CF_FANCONTROL_%1"[CR]
"OFF" ---------------------------- Set Fan control to Off
"ON1" ---------------------------- Set Fan control to On1
%1
"ON2" ---------------------------- Set Fan control to On2
"ON3" ---------------------------- Set Fan control to On3
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.25 CF_FILTIMER Command
Command
"CF_FILTIMER_%1"[CR]
"100" -------------------- Set 100 hours
"200" -------------------- Set 200 hours
"300" -------------------- Set 300 hours
"OFF" ------------------- No warning display
%1
"UP" --------------------- Switch Filter timer forward
"DN" --------------------- Switch Filter timer backward
Details
Set timer of Filter replacement /clean-up warning display.
Acceptable
Response
Unacceptable
8.10.26 CF_FILH Command
Command
"CF_FILH_%1"[CR]
%1
"RST" ---------------Reset Filter used time
Details
Reset filter used time
Acceptable
Response
Unacceptable
8.10.27 CF_FDEFAULT Command
Command
"CF_FDEFAULT_%1"[CR]
%1
"RST"
Set the value to Factory Default
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
(Off →100 → 200 → 300 → Off)
(Off → 300 → 200 → 100)
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]