PLC-XW200/250 Expand Serial Command Functional Specifications
8.10.21 CF_FANCONTROL Command
Command
"CF_FANCONTROL_%1"[CR]
"OFF" ---------------------------- Set Fan control to Off
"ON1" ---------------------------- Set Fan control to On1
%1
"ON2" ---------------------------- Set Fan control to On2
"ON3" ---------------------------- Set Fan control to On3
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.22 CF_CCAPTIONDISP Command
Command
"CF_CCAPTIONDISP_%1"[CR]
"OFF" ------------- Select Off
"CC1" ------------- Select CC1
%1
"CC2" ------------- Select CC2
"CC3" ------------- Select CC3
"CC4" ------------- Select CC4
Select channel of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
Details
This command is available in normal Power ON status.
Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video, Component=480i)
and System is fixed to NTSC or 480i.
Acceptable
Response
Unacceptable
8.10.23 CF_CCAPTIONCOLOR Command
Command
"CF_CCAPTIONCOLOR_%1"[CR]
"COLOR" ------- Select Color
%1
"WHITE" -------- Select White
Select color of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
Details
This command is available in normal Power ON status.
Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video, Component=480i)
and System is fixed to NTSC or 480i.
Acceptable
Response
Unacceptable
8.10.24 CF_FILTIMER Command
Command
"CF_FILTIMER_%1"[CR]
"100" -------------------- Set 100 hours
"200" -------------------- Set 200 hours
"300" -------------------- Set 300 hours
"OFF" ------------------- No warning display
%1
"UP" --------------------- Switch Filter timer forward
"DN" --------------------- Switch Filter timer backward
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
ÿ Off →100 → 200 → 300 → Offÿ
ÿ Off → 300 → 200 → 100→ Offÿ
36 / 64