PLC-XD2200/2600
Expand Serial Command Functional Specifications
8.10.21 CF_KEYDIS Command
Command
"CF_KEYDIS_%1"[CR]
"NONE" ----------------------- RC & Projector keys are valid (All are valid)
%1
"RC" ---------------------------- RC keys are invalid
"KEY" -------------------------- Projector keys are invalid
Disable RC/Projector keys
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.22 CF_PJPINCODE Command
Command
"CF_PJPINCODE_%1"[CR]
%1
"0000" – "9999" ---------Set PJ PIN CODE directly
Set PJ PIN CODE to release PJ LOCK.
PIN CODE cannot be changed by this command.
-When PJ LOCK is in operation
PIN CODE is correct ------------------------- Command is valid (Acceptable)
PIN CODE is incorrect ----------------------- Command is invalid(Error Code"102")
PIN CODE is out of %1 range ------------- Command is invalid (Error Code "? ")
Details
-When PJ LOCK is not in operation
PIN CODE is within %1 range ---------------- Command is valid (Acceptable)
PIN CODE is out of %1 range ---------------- Command is invalid (Error Code "? ")
This command is valid during a dialog "PJ PIN CODE" is displayed after Power On
and Count down.
Also when PJ LOCK setting is "On1", it is necessary to transmit this command
every time lamp turns on.
Acceptable
Response
Unacceptable
8.10.23 CF_FANMODE Command
Command
"CF_FANMODE_%1"[CR]
"L1" ---------------------------- Set Fan Mode to L1
%1
"L2" ---------------------------- Set Fan Mode to L2
Switch Fan Mode
When L1 is selected, fan noise after POWER OFF is louder.
When L2 is selected, fan noise after POWER OFF becomes quiet, however, fan
Details
rotates longer than L1.
The status set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
40 / 71