Cf_Fancontrol Command; Cf_Ccaptiondisp Command; Cf_Ccaptioncolor Command; Cf_Filtimer Command - Sanyo PLC-XW300 - 3000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XW300 - 3000 Lumens:
Table of Contents

Advertisement

PLC-XW200/250/300
Expand Serial Command Functional Specifications

8.10.21 CF_FANCONTROL Command

Command
"CF_FANCONTROL_%1"[CR]
"OFF" ---------------------------- Set Fan control to Off
"ON1" ---------------------------- Set Fan control to On1
%1
"ON2" ---------------------------- Set Fan control to On2
"ON3" ---------------------------- Set Fan control to On3
Set Fan control setting.
The status set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.22 CF_CCAPTIONDISP Command

Command
"CF_CCAPTIONDISP_%1"[CR]
"OFF" ------------- Select Off
"CC1" ------------- Select CC1
%1
"CC2" ------------- Select CC2
"CC3" ------------- Select CC3
"CC4" ------------- Select CC4
Select channel of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
Details
This command is available in normal Power ON status.
Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video, Component=480i)
and System is fixed to NTSC or 480i.
Acceptable
Response
Unacceptable

8.10.23 CF_CCAPTIONCOLOR Command

Command
"CF_CCAPTIONCOLOR_%1"[CR]
"COLOR" ------- Select Color
%1
"WHITE" -------- Select White
Select color of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
Details
This command is available in normal Power ON status.
Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video, Component=480i)
and System is fixed to NTSC or 480i.
Acceptable
Response
Unacceptable

8.10.24 CF_FILTIMER Command

Command
"CF_FILTIMER_%1"[CR]
"100" -------------------- Set 100 hours
"200" -------------------- Set 200 hours
"300" -------------------- Set 300 hours
"OFF" ------------------- No warning display
%1
"UP" --------------------- Switch Filter timer forward
"DN" --------------------- Switch Filter timer backward
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
ÿ Off →100 → 200 → 300 → Offÿ
ÿ Off → 300 → 200 → 100→ Offÿ