ADVANCED PROGRAMMING
To program sensors to send their signals to a different zone, you must first clear
them from communicating with their current zone.
TO CLEAR A ZONE
1. Enter the current MPIN.
2. Press [ B ].
3. Press the number key to identify current zone [ 1, 2, 3 or 4 ].
The zone light(s) will flash for eight seconds.
4. While the zone light(s) are flashing, press [ * ].
Now both the green and red lights flash for 30 seconds.
5. Do not activate any sensors while these lights are flashing.
Once the lights stop flashing, the zone is cleared of all devices.
Now that you have cleared the zone from communicating with all sensors, program
the sensors to the zones you would like them to communicate with (see below).
TO PROGRAM A SENSOR TO A ZONE:
1. Enter the current MPIN.
2. Press [ B ].
3. Press the number key to identify which zone to add the sensor to, zone [ 1, 2, 3 or 4 ].
The zone light(s) will flash for eight seconds.
4. While the zone light(s) are flashing, press [ * ].
Now both the green and red lights flash for 30 seconds.
5. While the zone lights are flashing, go to the remote sensor you are adding and
activate it. Walk in front of the motion sensor or open the door/window.
You will hear a long beep, the zone light will stop flashing and the remote sensor
will now communicate to that zone.
Note : You can only add remote devices to a zone one by one, but you can not
remove them one by one. You must clear all sensors from the zone and add back
the ones you want.
TO PROGRAM THE MOTION SENSOR TO THE SECURITY CONTROL
PANEL (SC-001):
1. Power up the motion sensor.
2. Enter the current MPIN (Master Personal Identification Number).
3. Press [B].
20

STANDARD PROGRAMMING

Now that the system is installed and the sensors are communicating with the
Control Panel, it is time to learn how to do basic programming of your security
system. More advanced features are explained further in the manual, (see
Advanced Programming).
You can arm and disarm the system by using either the keypad on the Control
Panel or the 4 button keychain transmitter or keypad transmitter KP-434 (option).
TO ARM THE SYSTEM USING THE KEYPAD ON THE CONTROL PANEL
All programming sequences begin with the Master Personal Identification Number
(MPIN). There is only one MPIN which has been factory set at 0 0 0. You can also
assign up to 3 different Secondary Personal Identification Numbers (SPIN). For
more information on how to change your MPIN and how to add an SPIN, (see
PASSWORDS on page 17.18).
We have preprogrammed 6 different arm sequences to meet different circumstances.
For example, if you would like the system activated while you are in the premises,
the motion sensor will be turned off so you have the freedom to move about with-
out setting off the alarm. You can personalize any of these preprogrammed arm
sequences, (see Advanced Programming).
Arming sequences
Option 1: Away Sequence - To arm your system when you are the last person
leaving the premises.
1. Press the current MPIN [ 0 0 0 ].
2. Press [ B ].
3. Press [ C ].
You hear a long beep. The arm light and the red lights in zones 3 and 4 go on.
Both the green and red lights flash in zone 1 for 45 seconds which gives you 45
seconds to leave the premises before the system is activated. After 45 seconds,
both the green and red lights in zone 1 and 2 remain on. Upon re-entering the
premises through zone 1, or walking in the monitored area of the motion sensor,
zone 2, you have 30 seconds till the alarm sounds. The system gives you 30
seconds from the time you enter the premises, for example opening the front door,
to get to the Control Panel to deactivate the system. Zones 3 or 4 remain instant.
If any sensor in zone 3 and 4 are activated, the alarm sounds instantly.
Option 2: Home Sequence - To arm your system when someone remains in the
premises.
1. Press the current MPIN [ 0 0 0 ].
2. Press [ C ].