ADVANCED PROGRAMMING
STANDARD ARMING SEQUENCES
Each zone can be programmed to react 5 different ways when it receives a signal
from a remote sensor.
1. Chime Mode - represented by the green lights
When only the green light is on and the Control Panel receives a signal
from a remote sensor, the Control Panel emits a subtly two tone chime.
2. Instant Mode - represented by the red lights
When only the red light is on and the Control Panel receives a signal from
the remote sensor, the Control Panel will activate the siren instantly.
3. Delay Entry Mode - represented by the green and red lights
When both the green and red lights are on and the Control Panel receives
a signal from a remote sensor, the lights will flash and the Control Panel
will beep for 30 seconds before the alarm sounds. These 30 seconds
give you time to enter the premises and deactivate the alarm before the
siren sounds.
4. Delay Exit Mode - represented by the flashing of both the green and red lights
for 45 seconds
When both green and red lights are flashing, the control panel will not
recognize any remote sensors communicating to that zone. These 45
seconds allow you time to exit the premises before that zone is activated.
When the lights stop flashing, both green and red lights will remain on,
which is now in DELAY ENTRY MODE.
(See above for information on DELAY ENTRY MODE).
5. Off - neither the green nor the red lights are on.
The Control Panel will not recognize any signals from a remote sensor.
We have preprogrammed different combinations of the above modes to meet
different situations, (see STANDARD PROGRAMMING).
ADDITIONAL ARMING SEQUENCES
Below are three additional programming options you may want to use.
Option 1: Advanced Home 1 - use to secure the premises while staying in the
building. Delays the alarm to allow someone to enter the building and deactivate
the alarm.
1. Enter the current MPIN.
2. Press [ A ].
3. Press [ A ].
You will hear a long beep. The arm light, the red and green lights in zones 1 and
the red lights in zones 3 and 4 go on. Zone 1 has the entry delay to allow some-
one to enter through the front door and deactivate the system before the siren
sounds. This option does not have the exit delay so you are not able to leave the
22

TESTING YOUR SYSTEM

Before you learn how to use your security system, test to make sure that the door/
window sensors and the motion sensor are communicating with the Control Panel.
Set the Control Panel to CHIME MODE which will emit a subtly two tone chime
when any of the sensors are activated.
To set control panel to CHIME MODE
1. Enter your MPIN [0, 0, 0] on the Control Panel (MPIN is factory set at [0, 0, 0].
To change MPIN see MASTER PERSONAL IDENTIFICATION NUMBER (MPIN)
on page 17.
2. Press [ A ].
3. Press [ # ].
The red arm light and all 4 green lights above the numbers and beside the word
chime will go on. The system will now emit a chime sound when any sensor is
activated. The lights and sounds of the Control Panel are explained in the next
section (see Lights and Sounds).
The door/window sensors are factory set to communicate with zone 1 and the
motion sensor to communicate with zone 2. If you would like to have the sensors
communicate with a different zone, see PROGRAM SENSORS TO DIFFERENT
ZONES on page 19.
To test the Door/Window Sensor
Open the door/window and break the contact between the magnetic switch and
the magnet. A signal will then be sent to the Control Panel which will chime
telling you that the signal has been received. One of the four green lights on the
Control Panel will flash once as the chime sounds. If you open the front door, the
green light above the #1 (zone 1) will flash.
To test the Motion Sensor
Power up the motion sensor. Walk in the monitored area in front of the motion sensor.
Once movement is detected, a signal will be sent to the Control Panel. The Control
Panel will then emit a two tone chime and the green light above the #2 (zone 2)
will flash once. The motion sensor has been programmed to send its signal to
zone 2 in the Control Panel. It will take about 20 seconds for the motion sensor to
reset itself before it can send another signal.
If you have pets, have them walk in the monitored area to see if they activate the
motion sensor. If so, turn the motion sensor off if these pets have access to the
monitored area.