LIGHTS AND SOUNDS

Below is an explanation of the lights and sounds of the Control Panel.
LIGHTS
ACPWR light on
System is being powered by electrical current.
ACPWR light off
System is not receiving any electrical power.
LOBATT. light off
Backup battery is connected and working.
LOBATT. light flashing
Backup battery is weak, needs to be replaced.
ARM light off
System is disarmed.
ARM light on
System is armed.
ZONE LIGHTS
Green lights above #1-4
System will emit a two tone chime when a sensor is
activated, CHIME MODE.
Red lights below #1-4
System will sound alarm instantly when a sensor is
activated, INSTANT MODE.
Both green and red lights
System will beep steadily for 30 seconds when a
#1-4
sensor is activated, after the 30 seconds the alarm
will sound, DELAY ENTRY MODE.
Both green and red lights
Lights will flash for 45 seconds. All remote sensors pro-
flashing
grammed to that zone will not communicate with the
Control Panel for those 45 seconds, which gives you
time to exit the premises before the system is armed.
SOUNDS
Three short beeps
You have made a mistake, start again.
Long beep
You have successfully completed a command.
Short beep
You have pressed a key in the right order.
Two tone chime
A device has been activated in CHIME MODE.
Siren (3 minutes)
A device has been activated in INSTANT MODE.
Steady repeated beep
The alarm has been triggered in DELAY MODE.
You have 30 seconds to disarm the system before
the alarm sounds.
Two tone beep
System is set on exit delay, you have 45 seconds
to leave the premises once the system has been
activated. After the 45 seconds, the system emits
a two tone beep and the system is now armed.
If you make a mistake while programming, the Control Panel emits three short
beeps. That means the system has cleared and you must start the programming
sequence from the beginning. If you get lost in the programming sequence or
have made a mistake and want to start over again, press the [ * ] on the key pad
of the Control Panel until you hear three short beeps. This will clear the system,
then you can start again from the beginning. If no button is pressed for eight
seconds while in the middle of a programming sequence, the system will also
clear itself.
12
ADVANCED PROGRAMMING
4. Press the number key to identify which zone to add the Motion Sensor to [1, 2,
3 or 4]. We recommend you program the motion sensor to zone 2. The zone
light will flash for eight seconds.
5. While the zone light is flashing, press [ * ].
6. While the zone light is flashing, press the learning button inside the battery
compartment of the Motion Sensor in order to activate it. You will hear a long
beep if the motion sensor is "learned" to the control panel. The zone light will
stop flashing and the remote sensor will now communicate to that zone.
TO DELETE A KEYCHAIN TRANSMITTER FROM ZONE 5:
1. Enter the current MPIN.
2. Press [ B ].
3. Press [ 5 ].
4. Press [ * ].
5. Do not activate any Keychain Transmitters or sensors for 30 seconds after the
[ * ] was pressed.
You have now cleared zone 5 from communicating with all Keychain Transmitters.
Please re-program the keychain transmitters that you would like to use by the
following instruction.
TO PROGRAM A KEYCHAIN TRANSMITTER OR KEYPAD TRANSMITTER
(OPTION) TO ZONE 5:
1. Enter the current MPIN.
2. Press [ B ].
3. Press [ 5 ].
4. Press [ * ].
5. Within 30 seconds of pressing the [ * ], press any of the four buttons on the
Keychain Transmitter OR press the panic button on the Keypad Transmitter.
You will hear a long beep and the Keychain Transmitter will now communicate
with zone 5.
NOTE: Zone 5 is designated for keychain and keypad transmitter ONLY.
Please do not program any sensors other than keychain and keypad transmitters
into zone 5, otherwise the system will not work properly.