WARNING
!
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.
11. Reinstall the hanger ball on the downrod as
follows. Route the motor leads through the hanger
ball and slide the hanger ball over the downrod
(Figure 7). Install the pin through the holes at the
top of the downrod and slide the hanger ball up
the downrod, aligning the ball so the pin is
captured in the groove in the top of the hanger
ball. Pull the hanger ball up tight against the pin
and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.
HANGER BALL
DOWNROD
CEILING COVER
Figure 7
12. Use three 10-24 x 3/8" pan head screws and flat
washers (supplied) to secure flange to blade
(blades ordered separately) (Figure 8). Repeat for
the remaining four blades.
Figure 8
13. Using the 5/32" hex wrench (supplied), loosen the
setscrew in the collar and unscrew (counterclock-
wise) the switch housing assembly from the motor
shaft (Figure 9). Do NOT remove the flat washer
from the motor shaft.
COLLAR
Figure 9
PIN
SETSCREW
10-24 x 3/8" PAN HEAD
SCREW (3)
FLAT WASHER (3)
BLADE
BLADE FLANGE
SWITCH HOUSING ASSEMBLY
SETSCREW
14. Use the 10 round recessed holes in the motor hub
marked with "5" and install the five blade assemblies
in accordance with Step 15.
15. Loosely attach one blade assembly to the motor
hub using two 10-32 x 5/8" oval head screws
(supplied) (Figure 10). Make sure the screws are
NOT tightened at this time. Repeat this procedure
for the four remaining blade assemblies.
16. The blade flanges have an interlocking feature that
must be fully engaged before tightening the
screws. Make sure all the flanges are properly
engaged and then tighten the flange screws In a
clockwise sequence. If one of the flanges does not
seat properly on the motor hub, loosen the
adjacent flange screws, re-engage and reseat the
flanges, then tighten the screws again.
BLADE FLANGE
FLAT WASHER
(DO NOT REMOVE)
Figure 10
!
To reduce the risk of personal injury, do not bend the
blade flanges when installing the flanges, balancing
the blades, or cleaning the fan.
17. Reinstall the switch housing assembly by passing the
wires from the motor shaft through the collar, screw
the assembly onto the motor shaft (Figure 11).
Tighten the setscrew using the 5/32" hex wrench
(supplied). Engage the connector from the switch
housing to the motor connector. The two connectors
are keyed and must be mated correctly before they
can be engaged.
SWITCH HOUSING
CONNECTOR
COLLAR
Figure 11
6
10-32 X 5/8"
OVAL HEAD SCREW
(3 PER BLADE
ASSEMBLY)
MOTOR HUB
WARNING
MOTOR
CONNECTOR
SETSCREW
SWITCH HOUSING
ASSEMBLY