9/19/07 11:15 AM Page 1 READ AND SAVE THESE INSTRUCTIONS JULIANNE ™ Ceiling Fan Owner's Manual Model Numbers CF220GLZ00 CF220GBZ00 Gilded Bronze with Gilded Silver with Dark Cherry/ Natural Cherry/ Walnut Blades Mahogany Blades CF220AGW00 Aged Walnut with Teak/Mahogany Blades 33.7...
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
Emerson Electric Co. Substitution of assembly parts or accessories not designated for i. One 6” downrod use with this product by Emerson Electric Co. could result in personal injury or j. One lower glass property damage. k. One decorative ring/light fitter assembly l.
Page 4
8. Sixteen flat washers 9. Three 8-32 x 7mm pan head screws 10. Two 1/8-27 nuts 11. One 1/8-27 lockwasher 12. One metal washer 13. One rubber washer 14. One hex wrench LIGHT FAN OFF EMERSON ® U.L. Model No.: CF220...
IMPORTANT: Your ceiling fan will not General function properly, Your Emerson ceiling fan comes supplied damaged, if used with any wall dimmer with a Fan/Light Wall Control which switch or control other than the consists of a wall control (transmitter) and...
Page 6
BP7360 JULIANNE 9/19/07 11:15 AM Page 6 5. Gently snug all flange screws to the 10-24 X 8mm PAN motor hub, working around the hub in a HEAD SCREW (3) clockwise sequence. Next, securely FLAT WASHER (3) tighten all flange screws, again working in a clockwise sequence.
Page 7
BP7360 JULIANNE 9/19/07 11:15 AM Page 7 8. Carefully rest the decorative ring/light fitter/switch cup assembly on the fan blades, then engage the connector of the switch cup assembly with the motor SWITCH CUP connector (Figure ASSEMBLY connectors are keyed and color-coded and must be mated correctly (color-to- color) before they can be engaged.
Page 8
BP7360 JULIANNE 9/19/07 11:15 AM Page 8 11. Remove the hanger ball by loosening WARNING the setscrew in the hanger ball until It is critical that the clevis pin in the motor the ball falls freely down the downrod coupling is properly installed and the (Figure 7).
Page 9
BP7360 JULIANNE 9/19/07 11:15 AM Page 9 WARNING It is critical that the pin in the hanger ball SCROLL SCROLL COLLAR is properly installed and the setscrew RETAINING securely tightened. Failure to verify that SCREW the pin and setscrew are properly SETSCREW DOWNROD installed could result in the fan falling.
BP7360 JULIANNE 9/19/07 11:15 AM Page 10 How to Hang WARNING Your Ceiling Fan Hanger bracket must seat firmly against outlet box. If the outlet box is WARNING recessed, remove wall board until bracket contacts box. If bracket The fan must be hung with at least 7' and/or outlet box are not securely of clearance from floor to blades attached, the fan could wobble or...
BP7360 JULIANNE 9/19/07 11:15 AM Page 11 How to Wire including ground, and that no bare wire is visible at the wire connectors, except Your Ceiling Fan for the ground wire. If you feel that you do not have enough 2.
Page 12
11:15 AM Page 12 SW101 FAN/LIGHT WALL CONTROL (SUPPLIED) BLACK BLACK (HOT) BLACK LIGHT 120- FAN OFF VOLT WHITE ® EMERSON SUPPLY WHITE WHITE GROUND TWO-CONDUCTOR BLUE WHITE CABLE (WITH GROUND) BLACK GREEN WIRE (GROUND) BLUE FROM HANGER BALL AND...
Page 13
Control and Receiver LIGHT (Figure 18) BLACK FAN OFF ® EMERSON Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four NEUTRAL GROUND levers (numbered 1, 2, 3, and 4) on the...
Page 14
In new construction, only one traveler wire Is required. LIGHT 3-WAY WIRlNG DIAGRAM: FAN OFF NEW CONSTRUCTION EMERSON ® FAN/LIGHT WALL FAN/LIGHT LIGHT LIGHT WALL CONTROL...
(Figure 24) and turn the fan on TRAVELER WIRES LOAD again. The blades will turn in the opposite direction and reverse the airflow. LIGHT LIGHT FAN OFF FAN OFF EMERSON ® EMERSON ® FAN/LIGHT WALL CONTROL TRAVELER WIRES LOAD Figure 22 LIGHT...
BP7360 JULIANNE 9/19/07 11:15 AM Page 17 WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1.
9/19/07 11:15 AM Page 18 Repair Parts LIGHT FAN OFF EMERSON ® Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER •...
Page 19
BP7360 JULIANNE 9/19/07 11:15 AM Page 19 Repair Parts Listing Part Numbers Model No. Model No. Model No. Description CF220AGW00 CF220GLZ00 CF220GBZ00 Hanger Pack, Consisting of: 761655-56 761655-55 761655-54 Hanger Bracket — — — Hanger Ball — — — Downrod —...
If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Electric Co. will refund the actual purchase price of your fan.
Need help?
Do you have a question about the JULIANNE CF220GBZ00 and is the answer not in the manual?
Questions and answers