Emerson Botanica CF2500HTW01 Owner's Manual page 5

Emerson ceiling fan cf2500ob01 cf2500htw01 cf2500s01 cf2500tg01 owner's manual botanica series
Table of Contents

Advertisement

5. Using wiring connectors (supplied), connect the
white, red, blue, brown, and yellow wires from the
downrod to the white, red, blue, brown and yellow
wires of the ceiling fan (Figure 4). Wires must be
connected color-to-color.
SW375 RECEIVER
YELLOW WIRE
TO YELLOW
WIRE
BLUE WIRE
WHITE WIRE
TO
RECEIVER
BLUE WIRE
CONNECTOR
WIRING HARNESS
CONNECTOR
BLACK WIRE
DOWNROD
RED WIRE
TO RED WIRE
BROWN WIRE
TO BROWN WIRE
BLUE WIRE
TO BLUE WIRE
WHITE WIRE
BLACK WIRE
TO WHITE WIRE
(NOT USED)
FAN
YELLOW WIRE
HOUSING
TO YELLOW WIRE
Figure 4
6. Fold all wires from the downrod into the slot in the
motor coupling, slide the downrod down the wires
and seat the downrod in the motor coupling. All
wires and wire connectors should be placed
through the motor coupling slot beneath the down-
rod (See Figure 5).
7. Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip. The clevis pin
must go through the holes in the motor coupling
and the holes in the downrod (Figure 5). Push the
straight leg of the hairpin clip through the hole near
the end of the clevis pin until the curved portion of
the hairpin clip snaps around the clevis pin. The
hairpin clip must be properly installed to prevent
the clevis pin from working loose.
WARNING
!
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed could result in the fan falling.
8. Install the setscrew (supplied in the loose parts
bag) in the motor coupling and tighten using the
5/32" setscrew wrench (supplied) (Figure 5).
WHITE WIRE
BLACK WIRE
LISTED GENERAL
USE ON/OFF
WALL SWITCH
(MUST BE
USED WITH SR330
REMOTE CONTROL)
WHITE
BLACK
WIRE
WIRE
TO
120V SUPPLY
SW350
WALL
CONTROL
TO
120V SUPPLY
LIGHT FIXTURE
FAN BLADES REMOVED
FOR CLARITY
LEADS TO BE
POSITIONED IN
SLOT IN MOTOR
COUPLING
SETSCREW
CLEVIS PIN
HAIRPIN
CLIP
CLEVIS
PIN
Figure 5
NOTE: Make sure the unused black motor lead is
capped with a wire connector. Make sure all wire
connectors are completely inside motor coupling
cover and not pinched between the motor
coupling cover and motor.
9. Screw two 1" threaded studs (supplied) into the
motor (Figure 6). Leave approximately 7/8" of the
stud extending above the motor. Slide the motor
cover over the downrod and rotate the cover until
the threaded studs protrude; install two knurled
knobs (supplied) to secure the cover.
MOTOR
Figure 6
10. Position the ceiling cover over the downrod. Be
sure the cover is oriented correctly, with the large
opening at the top (Figure 7).
5
DOWNROD
HAIRPIN
CLIP
MOTOR
COUPLING
DOWNROD
CLEVIS
PIN
MOTOR
COUPLING
KNURLED KNOB
MOTOR
COUPLING
COVER
WIRE
CONNECTORS
1" THREADED
STUD
7/8"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents