4.5
Front end position of the feeding clamp
66
1
Caution: Danger of injury !
Switch off the main switch.
Adjust the feeding clamp with utmost caution.
–
Move towards the reference point (switch 1).
–
Select version A or D/B/F.
The feeding clamp runs to the front end position.
–
Dimensional check of the front edge of the feeding clamp
(see chapter 6)
Example Version A:
Spacing A + sewing length + 15 mm
Consequently the front edge of the feeding clamp must have the
dimensions 111+180+15 = 306 mm from the middle of the needle.
–
Measure the difference between the actual position and the
determined nominal position.
–
Switch off the main switch.
–
Correct switch 1 by the difference .
–
Correct the rear stop guide 5.
–
Switch on the main switch.
–
Make another reference run and check the dimensions of the front
edge of the feeding clamp.
5