3.1.1

Position of the limit switch in the slotted hole

3.1.2

Distance between switching screw and limit switch

3.1.3
Stop for transport carriage
Checking
Unscrew screws 7 and take off the covering cap 6.
Check the position of the limit switch 1 in the slotted hole 2.
Correction
Loosen the upper counternut at the limit switch 1.
Set the limit switch in the slotted hole 2 as described in chapter
4.5.
Tighten the upper counternut again.
Attention: Danger of breakage !
After operations on the limit switch always check the distance to the
switching screw.
Checking
Unscrew screws 7 and take off the covering cap 6.
Push the transport carriage 4 to the very back.
Check the distance of 1 mm between limit switch 1 and switching
screw 3.
Correction
Pull the transport carriage 4 to the front until the switching screw 3
between the holding arms 9 is accessible.
Loosen the counternut at the switching screw.
Adjust the height of screw 3.
Distance between switching screw and fastening surface = 16 mm.
Tighten the counternut.
Push the transport carriage 4 to the very back.
Set a distance of 1 mm between limit switch 1 and screw 3.
Checking
Push the transport carriage 4 to the back until the surface of the
switching screw 3 stands centrically above the limit switch 1.
Check whether in this transport carriage position the distance
between the stop 5 and the transport carriage amounts to 2 mm.
Correction
Push the transport carriage to the back until the surface of the
switching screw 3 stands centrically above the limit switch 1.
Loosen counternut 8.
Approach the stop 5 to the transport carriage by 2 mm.
Tighten counternut 8.