Duerkopp Adler 745-34 Service Instructions Manual page 18

Sewing unit for runstitching of piped flap and welt pocket openings and pocket corners working methods: a, b, d, f
Table of Contents

Advertisement

16
13
12
11
Loosen the counternut 12.
Loosen the adjusting screw 13 a bit.
ATTENTION !
Do not loosen both adjusting screws 13.
With the two adjusting screws 13 the correct height of the linkage
frame has been set by the manufacturer.
ATTENTION !
Avoid damage to the oil wick when taking off the needle bar.
Note the position of the oil wick for the subsequent assembly.
Carefully remove the support plate 9 with the needle bar linkage 10
from the stop pin 11.
This is facilitated by slight turning motions.
10
9