5.6 Adjusting the fullness of needle and bottom feed
Operator terminal in case of fullness adjustment
adjustment
via cylinder
1
Operator terminal in case of fullness
via step motors
(optional equipment)
Needle feed, bottom feed and puller feed can be adapted to the sewing
conditions with the dials 1 and 2.
Via the control parameters you can determine which feed is changed
with the dial 2.
Adjusting the puller feed
–
Set the dial 1 correspondingly.
Setting range:
Adjusting the needle and bottom feed
–
Make the corresponding settings in the control in the menu
"Seam-specific parameters".
–
Set the dial 2 correspondingly.
Setting range:
2
1
+ 0 to 6 right
- 0 to 6 left
+ 0 to 6 right
- 0 to 6 left
1
17