17.3 Master reset

A master reset resets all parameter values to their factory settings.
Turn off the main switch.
Press the "P" key and turn on the main switch.
Release the "P" key..
Enter code no. "1907".
Press the "E" key. The parameter F-100 is displayed.
Press the "E" key. The value of the parameter F-100 is displayed.
Set the value to 170.
Press the "P" key twice.
Turn off the main switch.
After a brief waiting period turn the main switch back on.
All parameters have now been restored to their pre-set values.
Caution !
A few parameters, like F-111, F-161, F-170, F-171 and F-190
to F-194 for example, are not affected by a master reset.
All machine-specific parameters must be reset again in
accordance with the parameter sheet.