6.12

Master Reset

All parameter values are returned to their delivery status (preset values) through a
master reset.
Note
During a master reset all external consumers, e.g. sewing foot lift, must be turned off.
For this reason the 37-pin plug "A" of the machine connection should be unplugged
from the drive controls.
Turn the main switch off.
Unplug 37-pin plug "A" from the drive controls. (See section 6.6)
Press the "P" key and turn the main switch on.
Release the "P" key.
Enter code number "1907". See Chapter 6.10.2.2 and/or 6.10.2.3
Press the "E" key. The parameter F-100 is shown.
Press the "E" key. The value of the parameter F-100 is shown.
Set the value to 170.
Press the "
" key twice.
P
Turn the main switch off.
Insert 37-pin plug "A". (See section 6.6)
Turn the main switch on after a brief wait. All parameters, except 111, 161, 170,
171 and 190 to 193, have the preset values that were set at the factory again.
NOTE !
With a master reset certain parameters, such as e.g. F-170
(reference position), F-171 (needle position) and F-161
(motor direction of turn) are not reset.All parameters which
are set specifically for the machine must be set again as
per the Parameter Sheet.See Chapter 6.11