6.2.3
Checking the set positions
6.3
Master reset
1. Position
Turn the main switch on.
Step forwards slightly on the pedal and then release. The machine will
stop in the first position (refer to 6.2.1).
The number 225° (± 5°) on the handwheel scale is aligned with the
mark on the arm.
2. Position
First step slightly forwards on the pedal. Then press backwards with
your heel until the machine stops.
The machine will stop in the second position (refer to 6.2.1).
The number 35° (± 5°) on the handwheel scale is aligned with the mark
on the arm.
All changed values will be reset to their pre-set default values after a
master reset is executed.
After a master reset, all machine-specific parameters must once again
be properly set.
This is described in the booklet entitled "Instructions for Efka
Operation".