W
3
4
2. Positioning the counter-knife 3, the spring clip 4 and
the thread pulling knife 12.
–
Screw the throat plate off,
loosen the fastening screws of counter-knife 3.
Screw the gauge W (part no. 0767 290070) on the centerpiece
–
support 15.
Use the fastening screws of the centerpiece support 15 for this
purpose.
–
Position the counter-knife 3 in such a way that it abuts on the
gauge.
–
Make the spring clip 4 abut on the centerpiece support 15.
15
–
Screw on the thread pulling knife 12, make the point abut on the
front gauge cutout and tighten with the screws under slight pressure
in the direction of the counter-knife 3.
–
Adjust the spring clip 4 with a clearance of approx 0.2 mm to the
thread pulling knife 12 and tighten the fastening screws of the
counter-knife 3.
Screw the gauge W off again.
–
Standard checking
In the rear position of the thread pulling knife 12 the spring clip 4 should
slightly hold the bobbin thread.
If required, loosen the screws of the spring clip 4 and correct (bring the
thread pulling knife 12 in front position). Do not alter the adjustment of
the counter-knife.
GB
12
65