Setting The "Speedomat" Function - DURKOPP ADLER 767 Service Instructions Manual

Hide thumbs Also See for 767:
Table of Contents

Advertisement

18.2 Setting the "Speedomat" function

18.2.1
Setting the "Speedomat" function by means of control panel V810
9 . 3500
10
19
9 . 3500
12 . 3160
10
19
10
19
For the "Speedomat" function the following values must be set.
The maximum speed of the machine at minimum stroke height is
set with the parameter F-111 (n2 - see parameter sheet).
The speed at maximum stroke height is set with the parameter
F-117 eingestellt (n10 - see parameter sheet).
The upper "speed breaking point" is the Speedomat step up to
which the maximum speed F-111 is effective. The speed limitation
begins with the next step. The adjustment is effected with the
parameter F-188.
The lower "speed breaking point" is the Speedomat step from
which the speed is limited to F-117 (n10). The adjustment is
effected with the parameter F-188.
Display V810 Control Panel
11.2400
Speed step
Speed
Display V820 Control Panel
1)
3500
1)
= Speed
3)
= current Speed step
Minimum sewing foot stroke = no speed limitation = maximum speed n2
Maximum sewing foot stroke = maximum speed limitation = speed n10
The difference between maximum speed and speed at maximum stroke
adjustment is automatically and regularly distributed to the remaining
steps between the upper and the lower speed breaking point by the
control.
The programming of the automatic speed adaptation is done by the
competent technicians.
The adjustment of the upper and the lower speed breaking point is
effected with the parameter F-188.
Base for the settings are :
F-111 = 3500; F-117 = 2000; breaking point preset-value 10 + 19
Set maximum speed with parameter 111 (3500 min
Set stroke adjustment speed with parameter 117 (2000 min
Input of parameter F-188.
Press key "E".
The current Speedomat step (e.g. 9) and the matching speed
limitation (e.g. 3500) are indicated.
Press key ">>".
The current values for the upper speed breaking point (e.g. 10) and
the lower speed breaking point (e.g. 19) are indicated.
Press key ">>".
The current Speedomat step (e.g. 9) and the matching speed
limitation (e.g. 3500) are indicated.
Set new value for the upper speed breaking point (e.g. 12) by
means of the potentiometer, e.g. by turning the setting wheel.
Press key ">>".
The current values for the upper speed breaking point (e.g. 10) and
the lower speed breaking point (e.g. 19) are indicated.
Press key "E".
The new value (e.g. 12) for the upper speed breaking point is taken
over.
10
19
upper lower
breaking point
2)
3)
4)
10
9
19
2)
= upper breaking point
4)
= lower breaking point
GB
).
- 1
).
- 1
79

Advertisement

Table of Contents
loading