NOTE: W-84 Wall Control should only be installed on Casablanca's Inteli-Touch
or both an UPLIGHT and a DOWNLIGHT on the fan.
The wall control installs in the same manner as an ordinary light switch, using an existing wall box and wiring. This
controller is designed to signal the fan microcomputer as well as perform normal switching operations. For this
reason the following precautions must be observed:
1. Use only the Casablanca W-84 wall control.
2. Do not use any additional control with your Inteli-
Touch 3 fan (for example, dimmer, or fan speed
control).
Ensure power is turned OFF at the breaker or fuse panel before starting installation.
W-84 is used to describe either white (-11) or almond finish.
If you have multiple Inteli-Touch
"Changing Frequency Setting" on page 6.
1. Remove the screws and switch plate from the existing
switch box.
2. Remove the screws holding the switch in the switch box.
3. Pull the existing switch from the switch box to expose
the wire connections.
4. Remove the two wires from the switch.
5. Connect the BLACK wire from the POWER SOURCE
that you just removed from the switch to the BLACK/
WHITE STRIP wire on the W-84 wall control. Secure
this connection with a wire nut.
6. Connect the second BLACK wire that you just removed
from the switch to the second BLACK wire on the
located on the back of the W-84 wall control. Secure
this connection with a wire nut.
7. Connect the green ground wire coming from the back
of the W-84 control to the ground wire in the switch box.
Secure the splice with a wire nut.
NOTE: The RED wire is not used in this
application. DO NOT remove the crimped cap
from the wire.
8. Check your work by using the wiring
diagrams as shown in Figures # 1 and #2.
9. Install the W-84 in the wall box with the
two long screws provided.
10. Install the wall plate with the two color-
matched screws.
3
®
W-84 CONTROL INSTALLATION
INSTALLING THE W-84 WALL CONTROL
SINGLE W-84 INSTALLATION
CAUTION!
3 fans, refer to the section
®
3 fans with UPLIGHTS ONLY
®
3. Do not use more than one fan per wall control.
4. No other light fixtures or electrical appliances
may be connected on the circuit controlled by
the W-84 wall control.
2 BLACK
WIRES
(FIGURE #2)
(FIGURE #1)
W-84
Wall Control
RED WIRE
NOT USED
BLACK AND WHITE
STRIPED WIRE