en | Installation
4.5.2
Configuring the VideoJet X20
You can start the Configuration Manager immediately after installation.
1.
2.
3.
4.
5.
NOTICE!
i
You must reboot to activate the new IP address, a new subnet mask or a gateway address.
4.5.3
Reboot
You can trigger the reboot directly with the assistance of the Configuration Manager.
4.5.4
Additional Parameters
You can check and set additional parameters with the assistance of the Configuration
Manager. You can find detailed information on this in the documentation for this program.
V3.5 | 2007.12
Double-click the icon on the desktop or start the program via the Start menu. After the
program has started, the network is immediately searched for compatible video servers.
You can start the configuration if a VideoJet X20 is shown in the list in the left section of
the window. To do this, click the entry for the unit.
Click the Network tab in the right section of the window. The current network settings
are displayed.
In the Unit IP address field, enter the required IP address (for example 192.168.0.20)
and click the Set button at the bottom right of the window. The new IP address is valid
the next time you start the unit.
If required, enter a new subnet mask and additional network data.
Right-click the entry for the unit in the list in the left section of the window and select the
Reset command from the context menu.