5.29.1
Multicast address video 1 / Multicast address video 2
Enter a valid multicast address for each stream from the relevant encoder (video input) to be
operated in multicast mode (duplication of the data streams in the network).
With the setting 0.0.0.0 the encoder for the relevant stream operates in multi-unicast mode
(copying of data streams in the unit). The VideoJet X20 supports multi-unicast connections for
up to five simultaneously connected receivers.
NOTICE!
i
Duplication of data places a heavy demand on the unit and can lead to impairment of the
image quality under certain circumstances.
5.29.2
Port
Assign a different port to each data stream if there are simultaneous data streams at the same
multicast address.
Enter the port address of the required stream here.
5.29.3
Streaming
Click the checkbox to activate multicast streaming mode for the relevant stream. An enabled
stream is indicated by a check mark.
5.29.4
Multicast packet TTL
You can enter a value to specify how long the multicast data packets are active on the
network. This value must be greater than one if multicast is to be run via a router.