VideoJet X20
Malfunction
The unit does not report
an alarm.
Control of cameras or
other units is not
possible.
The unit is not
operational after a
firmware upload.
8.3

Malfunctions with iSCSI Connections

Malfunction
After connecting to the
iSCSI destination, no
LUNs are displayed.
After connecting to the
iSCSI destination, "LUN
FAIL" appears below a
node.
LUN mapping is not
possible.
Bosch Security Systems
Possible causes
Alarm source is not selected.
No alarm response specified.
The cable connection between
the serial interface and the
connected unit is not correct.
The interface parameters do not
match those of the other unit
connected.
Power failure during
programming by firmware file.
Incorrect firmware file.
Possible causes
Incorrect LUN mapping during
iSCSI system configuration.
The LUN list could not be read,
as it was assigned to the wrong
network interface.
Some iSCSI systems do not
support the use of an initiator
extension.
Installation and Operating Manual
Appendix | en 113
Recommended solution
Select possible alarm sources on
the Alarm Sources configuration
page.
Specify the desired alarm
response on the Alarm
Connections configuration page,
change the IP address if
necessary.
Check all cable connections and
ensure all plugs are properly
fitted.
Make sure that the settings of all
units involved are compatible.
Have the unit checked by
Customer Service and replace if
necessary.
Enter the IP address of the unit
followed by /main.htm in your
Web browser and repeat the
upload.
Recommended solution
Check the iSCSI system
configuration and reconnect.
Check the iSCSI system
configuration and reconnect.
Delete the initiator extension on
the iSCSI configuration page.