Gas adjustment (Conversion to LPG)
All work must be carried out by a CORGI registered
engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
Kind of gas
Natural
L.P.G.
Butane
Propane
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o Remove the pan-stands, burners and
flame spreaders (A).
o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table below).
GENERAL INJECTORS TABLE
Nozzle
Burners
mm/100
124
Wok
115
Rapid
97
Semi-rapid
72
Auxiliary
91
Wok
85
Rapid
65
Semi-rapid
50
Auxiliary
Power (in watts)
Max.
Min.
3300
1300
3000
750
1750
440
1000
300
3300
1300
3000
750
1750
440
1000
300