Gas adjustment (Conversion to LPG)
All work must be carried out by a GASSAFE registered
engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
Kind of gas
Natural
L.P.G.
Butane
Propane
o Reassemble all the burners carefully; in particular you should make
sure that the flame spreader is correctly placed on the burner.
o IMPORTANT: The minimum flow adjustment process must be
completed before the appliance is next used.
o Remove
flame spreaders (A).
o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table on next page).
GENERAL INJECTORS TABLE
Nozzle
Burners
mm/100
95/55/95
Wok
129
Rapid
97
Semi-rapid
76
Auxiliary
65/41/65
Wok
87
Rapid
65
Semi-rapid
51
Auxiliary
the
pan-stands,
Power (in watts)
Max.
3800
3000
1750
1000
3800
3000
1750
1000
burners
and
Min.
1700
1500
900
500
1300
700
400
350
24