Installing Mirrored Systems
How to upgrade an Enterprise platform to disk mirroring
CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
The root metadevice definitions go into the #metaroot section,
which you must create for the occasion; d20 goes into the #/cms
section, which already exists in the file. The swap metadevice
definitions go into the #swap section which, like #metaroot, must
be created for the occasion.
The lines you add must be in the following general format:
d< x> <y> 1 <device>
d <x> is the metadevice name.
<y> denotes the total number of disks named in the line.
1 <device> indicates one disk with the device name <device>. You
should have recorded the device names on
The pattern 1 (space) <device> repeats until all disks in the
metadevice have been named. The d12 entry must specify one disk;
the d20 entry must specify the same number of disks as the existing
d19 entry. If your system has two disks in slots 0 and 1 and you are
adding a two-disk mirror in slots 2 and 3, for example, you would
add the md.tab lines shown in boldface in the following sample:
-------- /etc/opt/SUNWmd/md.tab - EXAMPLE ONLY --------------
.
.
.
#metaroot
d11 1 1 c0t0d0s0
d12 1 1 c0t2d0s0
d13 -m d11
#/cms
d19 2 1 /dev/rdsk/c0t0d0s3 1 /dev/rdsk/c0t1d0s1
d20 2 1 /dev/rdsk/c0t2d0s3 1 /dev/rdsk/c0t3d0s1
d21 -m d19
#metaswap
(for load r3v6aj.c or later)
d15 1 1 c0t0d0s4
d16 1 1 c0t2d0s4
d17 -m d15
-------------------------------------------------------------
3. Save the /etc/opt/SUNWmd/md.tab file and quit the editor.
page
13.
19