Barco CLM HD8 R9050130 User Manual page 169

Hide thumbs Also See for CLM HD8 R9050130:
Table of Contents

Advertisement

4. Use the ▲ or ▼ key to select Overtemp DMD and press ENTER to toggle between [On] and [Off].
On
When temperature is too high, lamp mode is switched from 4 to 2 lamps. The 4 lamps mode can only be restored
after switching first to standby and restarting the projector.
If the temperature exceeds 64 °C, the projector is switched to standby.
Off
for a temperature between 60 and 64 °C the projector continues in normal operation but the warning is set on the
LCD display. Once the temperature is higher then 64 °C, then the projector is switched to standby.
The following text is displayed on the LCD: "DMD temperature to high. Please, check cooling liquid level ! Check
dust filters ! Press any key to confirm."
Image 14-55
R59770057 CLM HD8 15/03/2010
Image 14-56
Image 14-57
14. Service menu
165

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clm hd8 r90501301 clm hd8 r90501305Clm hd8

Table of Contents