Input Source Connections - Barco CLM HD8 R9050130 User Manual

Hide thumbs Also See for CLM HD8 R9050130:
Table of Contents

Advertisement

Light
output %
100
90
70
Image 5-3
Power input voltage versus light output (for R90501305)
Input power between 100V and 264V, the maximum light output with 4 lamps can be reached.
Input power between 90V and 99V, 83% of the light output with 4 lamps.
5.2

Input source connections

General
The input and communication unit is equipped with two input slots, which accept any type of input designed for the CLM projector.
The modularity of the input modules makes the CLM projector very flexible regarding input source connectivity. Note that the slot
numbering is done from top to bottom. So, the uppermost slot is slot number "1", the second is slot number "2". All input modules
have two status LED's. The green LED lights up if the input module is selected as the active input module. The yellow LED lights
up if the input module has detected valid input syncs.
1
2
Image 5-4
C
AUTION
jector.
R59770057 CLM HD8 15/03/2010
max. 3 lamps on
170
110
140
100
:
Always install a cover plate on an unused input slot. This to prevent dust intrusion into the pro-
4 lamps on
Input
264
voltage V
5. Connections
G
Y
37