5. SYSTEM MODE
While pressing the [FEED] and [PAUSE] keys at the same time, turn on the printer. Hold both keys
until the "<1>DIAG. Vx.x" Message appears.
Press the [FEED] key twice.
The printer is at the start of the Printer Parameter Fine Adjustment menu.
NOTES:
1.
When pressing the [FEED] and [RESTART] keys at the same time in the parameter
setting, the message returns to "<3>ADJUST SET".
2.
If holding the [FEED] or [RESTART] key for 0.5 seconds or longer in the Printer
Parameter Fine Adjustment, the key is entered continuously.
3.
A changed parameter becomes enabled by pressing the [PAUSE].
4.
Use the [FEED] or [RESTART] key to select a desired value or option.

5.5.1 Feed Length Fine Adjustment

With this parameter you can fine adjust the feed length. When "<3>ADJUST SET" appears,
press the [PAUSE] key.
Press the [PAUSE] key to start. Use the [FEED] or [RESTART] key to select a desired option.
[RESTART]
[FEED]
[FEED] key:
[RESTART] key: Pressing the [RESTART] key one time causes a +0.5mm change, up to +50.0
After completing the fine adjustment, press the [PAUSE] key.
Pressing the [FEED] key one time causes a –0.5mm change, up to –50.0 mm.
mm.
5.5 PRINTER PARAMETER FINE ADJUSTMENT
5-34
EO18-33012A