Electrical connection

The oven is designed to be connected to 230-
240V~(50Hz) electricity
supply.
The oven has an easily accessible terminal
block which is marked as
follows:
Letter L
-
Letter N
-
-
This oven must be earthed!
The cable used to connect the oven to the
electrical supply must comply to the specifica-
tions given below.
For UK use only
Min. size
Connection
Cable/
via
flex
Cooker
2,5 mm
Control
Circuit
It is necessary that you install a double pole
switch between the oven and the electricity
supply (mains), with a minimum gap of 3mm
between the switch contacts and of a type
suitable for the required load in compliance
with the current regulations.
The switch must not break the yellow and
green earth cable at any point.
Live terminal
Neutral terminal
Earth terminal
Cable/flex
type
2
PVC/PVC
twin and
earth
Important
After installation and connecting, the cable
must be placed so that it cannot at any point
reach a temperature of more than 50°C above
the ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply is
properly earthed.
The manufacturer declines any responsi-
bility should these safety measures not
be carried out.
Fuse
min:
15A
max:
20A