Gas connection

This appliance must be installed by a competent
person in accordance with the current versions of
the following UK (United Kingdom) or ROI (Republic
of Ireland) Regulations and Safety Standards or
their European Norm Replacements.
Important information
o This cooker is supplied to run on natural gas only and cannot
be used on any other type of gas without modification.
o Conversion for use on LPG and other gases must only be
undertaken by a qualified person. For information on the use of
other gases, please contact the Baumatic Technical Department.
o The cooker must be installed by a qualified person, in
accordance with the current edition of the Gas Safety
(Installation and Use) (Amendment) Regulations and the
relevant building/I.E.E. Regulations.
o Failure to install the appliance correctly could invalidate
Baumatic's guarantee and lead to prosecution under the
regulations quoted above.
o In the UK, CORGI registered installers are authorised to
undertake the installation and service work, in compliance with
the above regulations.
Ventilation requirements
o The room containing the cooker should have an air supply in
accordance with the current edition of BS 5440: Part 2:
o The room must have opening windows or equivalent; some
rooms may also require a permanent vent.
o If the room has a volume between 5 and 10m³, it will require an
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.
o If the room has a volume of less than 5m³, it will require an air
vent of 100cm² (effective area).
o If there are any other fuel burning appliances in the same room
the current edition of BS 5440: Part 2: should be consulted to
determine air vent requirements.