USERS
1. New Master Code
•
Master Code must be 6 digits-only.
•
Master Code is Keypad Code Access only.
•
Factory Default = 123456
•
See "Lock Design Overview" on page 5 for more information about Master Codes.
2. Add/Delete/Change User Codes 2-2000
•
User Number must be between 2 and 2000.
• To delete a code/card, leave the User Code blank and wait for the rapid beeping to stop, then
to avoid erroneously enrolling Proximity Cards, press and hold : for three seconds to exit
Programming Mode. If more programming is desired, re-enter Programming Mode.
• User Code must be 3-6 digits.
• Each User Code can be thought of as a person. As long as each person possesses their own
unique User Code, you can control access to the lock by adding or deleting User Codes. See
"Terminology Used in this Manual" on page 6 for more information.
See page 8. Users added will default to a Group Association and a Program Level Ability as follows:
USER TYPE
Master
Installers
Managers
Supervisors
Print Only Users
Basic Users
Basic Users in Group 1
Basic Users in Group 2
Basic Users in Group 3
Basic Users in Group 4
Basic Users
Quick Enable User 300
Quick PC Access
AL-DTM2 Code
Service User
Basic Users
User 299 is a Non-Pass Code. This is the only code that will initiate data transfer with the AL-DTM.
16
Programming Functions
(User Number 1)
Lock Defaults for PDL3000/3500 & ETPDL
USER NUMBER
1
2 & 3
4 - 6
7 - 9
10 - 11
12 - 50
51 - 100
101 - 150
151 - 200
201 - 250
251 - 296
297
298
299
300
301-2000
; 1
;
[ _ _ _ _ _ _ ]
(New Master Code)
; 2
;
[ _ _ _ _ ]
(User Number)
GROUP DEFAULT
ASSOCIATION
-
none
none
none
none
none
1
2
3
4
none
none
none
none
none
none
;
[ _ _ _ _ _ _ ]
(Confirm New Master Code)
M
*
;
[ _ _ _ _ _ _ ]
(User Code)
3
MINIMUM PROGRAM
LEVEL (see page 6)
M (All Programming Abilities)
4 (Also 3, 2, 1)
3 (Also 2, 1)
2 (Also 1)
1
none
none
none
none
none
none
none
none
none
none
none
:
:
Need help?